UC100 - high-speed

Technical Specification

 
Specification Description
Indicator Power
Power Supply Voltage 90V to 245V AC, max 30W
Controller RTC Built, 32-bit high speed ARM7
A/D Converter
Type 24-bit Delta Sigma
Analogue Input Range 0 mV to 25 mV
Linearity <0.03% FS
Gain Drifting 2PPM/◦C
Conversion Rate 600 Samples/Sec
Internal Resolution 1 in 30,000
Display & Keypads
LCD Display 4 lines 20 character
LED Display 6 digits 7 Segment LED Display (size : 0.56")
Keypads Capacitive Sense 17 alphanumeric keys
Calibration & Weighing
Calibration Digital calibration by using standard weights
Weighing Functions Auto Zero, Power On Tare
Inputs& Outputs
Input Load cell
Serial Ports

Single RS485 Half Duplex Port and Two RS232 ports.

Connectors R/A pluggable terminal connectors
Collector Output 8 isolated open collector outputs for 500mA load current max
Isolated Inputs 8 isolated inputs for 24 VDC max
Load cells
Excitation 5 VDC
Load cells Drives 4 Load cells of 350 Ω
Mechanical Dimension
Cabinet Size 200mm (L)*125mm (H)*207mm (W)
Cutout Details 122mm (H)*206mm (W) with mounting hole 240mm (L) *60mm (H) at 4 holes 5mm diameter
Gross Weight 3.10 Kg
Environmental
Operating Temperature -10◦C to 40◦C
Storage Temperature -25◦C to 70◦C
Relative Humidity 90% R.H without dew
IP Level Front panel IP 55

Cumulative Online Batch Weigher I / O Details

 
S. No. Input parameter Description Output parameter Description 
1. START To start the batch cycle COARSE Feed hopper Operation 
2. STOP To STOP the batch cycle  FINE Fine Gate operation 
3. AUTO/MANUAL Auto manual I/P ERROR System Error 
4. GATE CLOSE Weigh  Hoper Gate close signal  DISCHARGE Weigh hopper Operation 
5. LEVEL Material Level Signal  BATCH END Batch Completion O/P
6. TARE Empty Hopper TARE Function BATCH STATUS System ON status O/P 
7. LOW PRESSURE Air pressure signal     

Bagging System  I / O Details

 
S. No. Input parameter Description Output parameter Description 
1. START To start the batch cycle COARSE Feed hopper Operation 
2. STOP To STOP the batch cycle  MEDIUM Medium Gate operation
3. KEYLOCK To lock the keypad FINE Fine Gate operation 
4. GATE CLOSE Weigh  Hoper Gate close signal  ERROR System Error 
5. LEVEL Material Level Signal  HAMMERING Hammering Function for material settlement 
6. BAG CLAMP To clamp the Bag BAG CLAMP Bag Clamp and Declamp function 
7. TARE Empty Hopper TARE Function  BATCH END Batch Completion O/P
8 DISCHARGE Material Discharge from Weigh hopper PROCESS System ON status O/P 
      SLIDE GATE Slide gate function  

Online Check Weigher  I / O Details

 
S. No. Input parameter Description Output parameter Description 
1. SENSOR Product Detection Sensor ACCEPT Accept Product O/P
2. LOW PRESSURE Low Air pressure signal  LOW REJECT Product Low reject O/P
3. TARE TARE Function  HIGH REJECT Product HIGH  reject O/P
4. KEY LOCK To lock the keypad REJECT Reject for Buzzer 
5. START To START the Conveyer  ERROR System Error 
6. STOP To STOP the Conveyer  AVERAGE ERROR Cumulative product Average 
      RUN Run the conveyer 

Jumbo Bagging  I / O Details

 
S. No. Input parameter Description Output parameter Description 
1. START To start the batch cycle COARSE Feed hopper Operation 
2. STOP To STOP the batch cycle  MEDIUM Medium Gate operation 
3. PAUSE/CONTINUE Batch PAUSE and Continue  FINE Fine Gate operation 
4. COMP SIGNAL HIGH Bag Lifting Cylinder HI Signal VIBRATOR Vibrator O/P during shacking 
5. COMP SIGNAL LOW Bag Lifting Cylinder Low Signal COMP CYLINDER Bag shacking Cylinder O/P
6. AIR PRESSURE Low Air pressure signal  BATCH END Batch Completion O/P
7. SLIDE GATE Slide gate Signal  AIR BLOW To Inflate the bag
8. LEVEL Material Level Signal